| Construction of New Building for PEL Examination Center, Karachi As per the BoQ attached as Annexure to this Document | 1 | 1 |
| Subtotal | — | — |
| D122 | — | — |
| Total for Daywork: Labour (carried forward to Daywork Summary, p. ) | — | — |
| Total for Daywork: Materials (carried forward to Daywork Summary, p. ) | — | — |
| Total for Daywork: Contractor’s Equipment (carried forward to Daywork Summary, p. ) | — | — |
| In the event of any out-break of illness of epidemic nature, the Contractor shall comply with and carry out such regulations, orders and requirements as may be made by the Government or the local medical or sanitary authorities for the purpose of overcoming the same. | — | 6.26 Epidemics |
| The following is added before the first paragraph: <Except as otherwise provided in the Contract,= The following is added at the end of the Sub-Clause: "No Plant and/or Materials that is the property of the Employer shall be removed from the Site. If it becomes necessary to: (i) remove any item of such Plant from the Site for the purposes of repair, the Contractor shall give a Notice, with reasons, to the Engineer requesting consent to remove the defective or damaged item off the Site. This Noti |
| — |
| 7.7 Ownership of Plant a |
| Engine: Fuel filter Oil filter Air filter Water filter Fan belt Water pump belt Alternator belt Rocker cover gasket Gasket Alternator & Panel: AVR Forward diodes Reverse diodes Fuses 2 amp Fuses 6/8 amp Fuses 10 amp | — | — |
| Civil Works | 1.2 | — |
| Electrical Works | 1.3 | — |
| Plumbing Works | 1.5 | — |
| CCTV System | 1.5 | — |
| Data Net Working | 1.6 | — |
| Grand Total Amount Rs:- | — | — |
| A- EARTH WORK | — | — |
| Clearing and grubbing the site by cutting, uprooting and removingall rubbish and shrubs including disposal to (outside limits) designated places. | 1 | Sft |
| Excavtion in foundation of Building Bridges and other structure sincluding dagbelling dressing, refilling ramming leadupto5 ft. , leaduptoonechain(30metre)andliftupto 5 ft. (1.5 metre). | 2 | Cft. |
| Filling, watering and ramming earth under floor with new earth (Excavated from outside)liftupto5ftandleadupto10miles including cost of earth. | 3 | Cft. |
| Providing and filling local sandy soil approved quality in set back, trenches, plinth/under floor or any section of work including dressing, watering, consolidation inlayersnotexceeding9"indepthatleast 95% Modified AASHTO specifications complete in all respect as per specification and as directed by the Engineer, | 4 | Cft. |
| Filling watering & ramming sweet earth excavated form outside leadupto 10 miles and lift upto 5ft.including cost of sweet earth | 5 | Cft. |
| B-TERMITTE PROOFING | — | — |
| Providing Anti-termite treatment by spraying/ sprinkling / spreading Neptachlar 0.5% Emulsion as an over all pre construction treatment in slab type construction under the slab and along attached perches or entrances etc, complete as per directions of Engineer | 5 | Sft. |
| Incharge | — | — |
| C- SUB & SUPER STRUCTURE | — | — |
| Cement concrete plain including placing compacting, finishing and curing, comlete including screening and washing at stone aggregate without shuttering. 1:4:8 | 6 | Cft. |
| Cement concrete plain including placing compacting, finishing and curing, comlete including screening and washing at stone aggregate without shuttering. 1:3:6 | 7 | Cft. |
| Reinforced cement concrete work includingall labour and material except the cost of steel reinforcement and its labour for bending and binding which will be paid separately.This rate also includes all kinds of forms moulds, lifting, centering, shuttering and curing. (including screening and washing of shingle.) a) R.C.Cwork in roof slab, beams, column, rafts, lintels andotherstructuralmemberslaidinsituor precast laid in position complete in all respects. (i) Ratio1:2:4 90 Lbs of cement,2 Cft san | 8 | Cft |
| Reinforced cement concrete work includingall labour and material except the cost of steel reinforcement and its labour for bending and binding which will be paid separately.This rate also includes all kinds of forms moulds: lifting shuttering and curing (including screening andwashing of shingle.) (a) R.C.Cwork in roof slab, beams, column, rafts, lintels andother structural members laid in situ or precast laid in position complete in all respects. (ii) (II)Ratio1:1-1/2:390Lbsofcement,1 1/2Cftsan | 9 | Cft |
| Fabrication of deformed steel reinforcement for cement concrete including cutting,bending, laying in position, making joints and fastenings includingcostofbindingwire(alsoincludes removeal of rust from bars.) a) Deformed bar i) Grade-60 | 10 | Kg |
| D - MASONARY | — | — |
| Providing and laying 1 : 3 : 6 cement concrete solid block masonary wall 6" and below in thickness set in 1: 6 cement mortar in ground floor Super Structure including raking out joints & currring etc, complet | 11 | Cft |
| Providing and laying 1 : 3 : 6 cement concrete solid block masonary wall 6" and below in thickness set in 1: 6 cement mortar in First floor Super Structure including raking out joints & currring etc, complet | 12 | Cft |
| E - JOINERY and CABINET | — | — |
| Flush Door | 13 | — |
| Providing and fixing in position doors of first class deodar wood frames, and1-3/4" thick comercial ply veneer shuttersof first class deodar skeleton (Solid Door) and commercial plywood (3ply) on both sides includinghold fasts, hinges, iron tower bolts,handlesandcleatswithcordandone Mortice lockand hooks | — | Sft |
| Solid Door | 14 | — |
| First Classdeodar wood wrought joineryin doors 2" thick panelled or glazed or fully glazedfixedinpositionincludingchowkhat, holdfast, hinges, towerbolt rubber stop cleats/GIclamp, handles and chord with hooksetc.complete(excludingslidingbolts or lock) | — | Sft |
| Door Lock | 15 | — |
| P/F approved quality of mortice lock. | — | Nos. |
| Door Closer | 16 | — |
| P/F approved quality of door closer in/c fixing on door with screws and adjusting speed on required etc complete. | — | Nos. |
| Wooden Beading | 17 | — |
| Providing&fixingupto3"widebestquality wood beading plain / decorative as approved design on doors or where requiredcompleteinallrespectinanyfloor atanyheighti/ccostofenamelpaintingor polishing as per instruction of Engineer | — | Rft |
| F- METAL WORK | 17 | — |
| Providing and fixing G.I frames /Choukhats ofsize10"x2"or41/2"x3"fordoorusing 16 gauge G.I sheet I/c welded hinges and fixing at site with necessary hold fasts, filling with cement sand slurry of ratio 1:6 andrepairingthejambs.Thecostalsoi/call carriage tools and plants used in making and fixing. | — | Rft |
| Providing and fixing stainless steel nickle coatedstaircaserailingof3-1/2''consisting of horizontal 2-1/2''x2-1/2'' at bottom and 1-1/2''x1-1/2'' vertical tube 12'' center to centerand3''steeltubewithroundballas directed by engineer / incharge. | 18 | Rft |
| Providi Providing and fixing iron steel grill using solid square bars of size 1/2" x 1/2" placedat 4"I/c andframe offlat ironpatti of 3/4" x 3/4" I/c circle shape at 1-0 apart equivalent fitted with screws are pins I/c painting3coatswith1stcoatofredoxide paint etc. | 19 | Sft |
| ProvidingandfixingGlassRailingofTerrace includingalltheaccessoriescompleteinall respects asper drawing, Specificationsand as instructed by the Engineer. | 18 | Rft |
| Providing and fixingof MS emergency Stair Complete in all respects asper drawings, Specifications and as instructed by the Engineer | 19 | Job |
| 19 NSI Supplyandinstall10"(250mm) sweep exhaust fan including plastic louvers. | — | Each |
| G- ALUMINIUM WORK | — | — |
| Supplying & fixing in position Aluminum channels framing 2mm thick for sliding windows& ventilators ofmade with 8mm thick tinted glass glazing etc. Complete. | 20 | Sft |
| Supplying & fixing in position Aluminum channels framing 2mm thick for hinged doorsormadewith8mmthicktintedglass glazing and Alpha locks I/c handles, stoppers etc.Hydralic Door Closer and complete accessories, | 21 | Sft |
| H- WALL FINISHES | — | — |
| Cement plaster 1:4 upto 12' height.3/4" thick | 22 | Sft. |
| Laying floors of approved coloured glazed tiles1/4"thickdadotilesofapprovedcolor & size jointing in white cement and laid over 1:2 cement sand mortor 3/4" thick including grouting with matching color and finishing | 23 | Sft |
| I - FLOORING & FINISHING | — | — |
| Crushing stone ballast by machine | 24 | Cft |
| Cement concrete plain including placing compacting, finishing and curing, comlete including screening and washing at stone aggregate without shuttering. 1:4:8 | 25 | Cft |
| Providing and laying 3" thick topping of cement concrete (1:2:4 ) including Surface finishing and dividiing into panels: | 26 | Cft |
| Providing & Laying Full Body Porcelain Tile 24"x24"x5/16" in Flooring or Facingof Approved Design Set inGry Cement Motor 1:2orof3/4"ThickinssI/Cwashing &Joints With White Cement Slurry Using Colour Pigment for matching complete as per Spacification | 27 | Sft |
| Laying Verona marble flooring Size 24"x12"x1"/12"x12"x1" finedressedon thesurface without winding set in limemortar 1:2 including rubbing and polishing of the joints. | 28 | — |
| For flooring & Skirting (pre polished) | — | Sft |
| Laying floors of approved coloured glazed tiles 1/4" thick floor of approved color & sizejointinginwhite cementandlaidover 1:2 cement sand mortor 3/4" thick including grouting with matching colorand finishing | 29 | Sft |
| P/F Granite Strips (5''x1''x1'') thick fixed over stair steps of required width set in cement sand mortar1:2 in gray cement 1''thick in/c washing and filling etc complete. | 30 | Sft |
| J - WATER PROOFING & ROOF INSULATION | — | — |
| Providing and applying water proofing on roof including surface preparation and plaster the salb with 1:4 cement sand mortar 3/4" thick, bitumincoating, insulation comprising of self extinguishing extruded closed cell polystyrene board 2" thick (35Kg/M3) , minimum 1-1/2" thick screed 1:2:4 as per slope mentioned in drawing, Aquafin IC, 1 kg per Sq. meter or as per manufactured recemondation and on the top 12"x12"x3/4" thick Cement Concrete tiles including insulation fixed with 1:4 cement sand ma | 31 | Sft. |
| Khuras,onroofsize2'x2'x4"(600x600x 100mm) | 32 | No |
| K - FALSE CEILING | — | — |
| Supplying and fixing false ceiling of plaster of paris in pannels including making frame work of deodar wood i/c painting With soliginum paint. | 33 | Sft. |
| Supplying and fixing 2'x2' PVC false ceiling of plaster of paris in pannels including Adjustable imported syspension system complete in all respects | 34 | Sft |
| L - PAINTING AND POLISHING | — | — |
| Plastic Emulsion | 34 | — |
| Preparing the surface and painting with plasticemulsionpaintofapprovedmakeI/c rubbing the surface withsand Paper,filling the voids with chalk/ plaster of paris and then painting etc. complete. A Three Coat | — | Sft |
| Preparing the surface and painting with matt finish I/c rubbing the surface with Bathy (silicon carbide rubbing brick) filling the voids with zink /chalk / plaster of parismixture, applying first coat premix, making the surface smooth and then painting 3 coats with matt finish ofapproved makeetc:complete.(new | 35 | Sft |
| surface). | — | — |
| Preparing the surface and painting with weather coat I/c rubbing the surface with rubbingbrick/sand Paper,filling thevoids with chalk/ plaster of Paris and then painting with weather coat of approved make. | 36 | Sft |
| Preparingthesurfaceandapplyingrockwall / shield (Naturalwalltexture) coating to providedurablecrusttowall,thicknessb/w 2mm to 32mm(1/8" )with acrylic co- polymer emulsion, selected marble chips, adhesive and bactericides. | 37 | Sft |
| Vertical damp proof course of 3/4" thick cementplaster1:2withbitumenat(20Lbs. Per % Sft. | 38 | Sft |
| M- EXTERNAL FINISH | — | — |
| Cement plaster 1:4 upto 12' height.3/4" thick | 39 | Sft |
| GRAND TOTAL OF CIVIL WORK (A+B+C+D+E+F+G+H+I+J+K+L+M) :- | — | — |
| Providing &laying (Main orSub Main) PVC insulated with size 3-3/.029 copper conductor in ¾" dia PVC conduit recessed in thewall orcoumn as required. | 1 | Rft |
| Providing &laying (Main orSub Main) PVC insulated with size 2-3/.036 copper conductor in ¾" Dia PVC conduitrecessedinthewallorcolumn as required. | 2 | Rft |
| Providing & laying (MAIN or SUB MAIN) PVC insulated with size 3-7/.029 copper conductor in ¾" Dia PVC conduit recessed in the wall or column as required. | 3 | Rft |
| Providing & laying (MAIN or SUB MAIN) PVC insulated with size 3-7/.036 copper conductor in ¾" Dia PVC conduit recessed in the wall or column as required. | 4 | Rft |
| Providing & laying (MAIN or SUB MAIN) PVC insulated & PVC sheeted with 4 core Armoured copper conductor 600/1000 volts size 16mm2 | 5 | Rft |
| Providing & laying (MAIN or SUB MAIN) PVC insulated & PVC sheeted with 4 core Armoured copper conductor 600/1000 volts size 25mm2 | 6 | Rft |
| Providing and Fixing flush type, 6/10 Amps fush type 2-pin piano socket fitted on given sheet all kind of board i/c connection as required. | 7 | Each |
| Providing & fixing Two pin 10/15amp plug & socket | 8 | Each |
| Providing &fixing threepin 10/15amp plug & socket flush type | 9 | Each |
| Providing & fixing three pin 20amp plug for AC | 10 | Each |
| Supply and install distribution board, 18SWGsteelsheet18"x24"enclosure, suitable for recess mounting, comprising one incoming MCCB- TP/100A,Outgoing9singlephaseMCB ofvariouscapacitywithinternalwiring earthing, neutral link etc. alongwith three Digital Amp. meters with lights. | 11 | Each |
| Providing & fixing circuit breaker 6, 10 , 15, 20,30,40,50&63 SP (TB-5S)on prepared board as reuqired | 12 | Each |
| Providing&fixingacryliccoverfor125 watts light @ as per site requirement & instruction of eingineer in charge | 13 | Each |
| Providing&fixingacryliccoverfor250 watts light @ as per site requirement & instruction of eingineer in charge | 14 | Each |
| Providing and Fising of Recess Mounted LED Panel Light 24"X24" (40W )including fixing in false ceiling complete in all respects as per drawings, Specifications and as instructed by the Engineer. | 15 | Each |
| Providing & fixing 125 watts (HPMV) chowk @ the height as per site requirement & instruction of engineer in charge | 16 | Each |
| Providing & fixing A.C Electric Ceiling fan 56" (good quality) | 17 | Each |