Loading…
Military Lands & Cantonments (ML&C) Military Land & Cantonments Deptt. (ML&C) Rawalpindi - Pakistan
Military Land & Cantonments Deptt. (ML&C) · Rawalpindi
| Item | Qty | Unit |
|---|---|---|
| Supply, installation, testing and commissioning of PV panel Tier-I for solar electric energy system, complete in all respect as specified | 578 | KW |
| Supply, installation, testing and commissioning of PV panel Tier-I for solar electric energy system, complete in all respect as specified | 1 | Watt |
| Supply, installation, testing and commissioning of Inverter for Hybrid solar electric energy system, complete in all respect as specified | 2 | Watt |
| Supply, installation, testing and commissioning of Lithium Iron Phosphate Battery for solar electric energy system, complete in all respect as specified | 3 | watt |
| DC Cable from Array to Inverter 1C x 70mmsq, Copper | 360 | Mtr |
| Supply and Installation of GI/ Aluminium frame structure (Roof Top Elevated Structure) including concrete work for solar electric energy system, complete in all respect as specified | 4 | watt |
| Battery Controller:BEES battery controller (supply fixing complete in all respect) | 5 | each |
| Genset Synchronization (gateway) 120KW supply and fixing, complete in all respect | 6 |
| each |
| Communication Cable for CT supply and fixing | 7 | meter |
| CTs :Ratio: 250/5 supply and fixing | 8 | each |
| MCCB 4 Pole, 500 / 600 V, 50/60 Cycles, complete with thermal and magnetic trip 3 to 30 A (Breaking capacity 2.5 KV), supply and fixing. | 9 | each |
| Steel Box (16 BG) for main switch, distribution board and meter, Type A, as per drawing in Figure 25-14, duly painted with primer and two coats of synthetic enamel paint, supply and fixing. | 10 | each |
| LT Switch Board with 1250 A, MCCB, incoming switch, complete with thermal over current release, adjustable magnetic short circuit release, shunt trip coil, CT ratio 1000/5, volt meter and Amp-meter with selector switches, earth fault relays, complete with TP, neutral common bus bar, including upto 06 outgoing with neutral link, 3-Phase MCCB switches, switch board steel sheet factory wired, painted and installed, complete including making connection, supply and fixing. | 11 | each |
| MCCB 4 Pole, 500 / 600 V, 50/60 Cycles, complete with thermal and magnetic trip 250A (Breaking capacity 2.5 KV), supply and fixing. | 12 | each |
| MCCB 4 Pole, 500 / 600 V, 50/60 Cycles, complete with thermal and magnetic trip 100A (Breaking capacity 2.5 KV), supply and fixing. | 13 | each |
| MCCB 4 Pole, 500 / 600 V, 50/60 Cycles, complete with thermal and magnetic trip 400A (Breaking capacity 2.5 KV), supply and fixing. | 14 | each |
| AC Surge Protection Devices Type II, supply and fixing, complete with all respect | 15 | each |
| Wiring in conduit surface, concealed, flame proof, with single core PVC insulated cable, installed and connected complete (excluding conduit) single core cable, 2.5 mm² (For Earthing), supply and fixing | 16 | meters |
| Wiring in conduit surface, concealed, flame proof, with single core PVC insulated cable, installed and connected complete (excluding conduit) single core cable, 4 mm² (For Earthing), supply and fixing | 17 | meters |
| Wiring in conduit surface, concealed, flame proof, with single core PVC insulated cable, installed and connected complete (excluding conduit) single core cable, 25 mm² (For Earthing), supply and fixing | 18 | meters |
| Cable electric LT, PVC insulated, PVC sheathed, un- armoured, overall PVC 600/1000 V, with stranded copper conductor 35 mm², but 3½ core, laid in trenches complete with bricks, sand (excluding cost of excavation), supply and fixing. | 19 | meter |
| do but 70mm | 20 | meter |
| do but 95mm | 21 | meter |
| do but 120 mm | 22 | meter |
| Supply, installation, testing and commissioning of DC Cable 6mm² double XLPO insulated and tin coated for solar electric energy system, complete in all respect as specified. | 23 | meter |
| DC Cable from Array to Inverter 1C x 70mmsq, Copper | 24 | meter |
| Lightning Arrester set of three pieces, complete, with all accessories, | 25 | each |
| Earthing :complete as described in Para 24.16 of the Specifications, with 3/0 SWG copper conductor, supply and fixing. | 26 | each |
| Excavation in hard soil for Cables | 27 | cum |
| Polyethylene Pipe (PE-100), 75 mm dia, Class PN-10 / SDR-17 (excluding cost of excavation), supply and fixing. | 28 | meter |
| Conduit, 50 mm dia, heavy gauge Class-"B", screwed, solid drawn, complete with all bends, tees, boxes saddels etc., stove enamelled for surface wiring, supply and fixing (fittings shall be flame proof and conform to BS No. 229 and 889). | 29 | meter |
| Net Metering: Provision for statutory charges payable to K-Electric and/or other Competent Authority in connection with grid interconnection and net- metering approval of the Solar PV System, including application fees, processing charges, bidirectional revenue metering charges, statutory inspection/testing charges (where levied by the utility), and any other mandatory statutory charges required for grant of grid interconnection approval. | 30 | job |
| added 2.65% on MES Shedule 2025 item | 31 | job |
| Supply, installation, testing and commissioning of Inverter for Hybrid solar electric energy system, complete in all respect as specified | 490 | KW |
| Supply, installation, testing and commissioning of Lithium Iron Phosphate Battery for solar electric energy system, complete in all respect as specified | 912 | KWh |
| Supply and Installation of GI/ Aluminium frame structure (Roof Top Elevated Structure) including concrete work for solar electric energy system, complete in all respect as specified | 578 | KW |
| CTs :Ratio: 250/5 supply and fixing | 12 | No. |
| MCCB 4 Pole, 500 / 600 V, 50/60 Cycles, complete with thermal and magnetic trip 3 to 30 A (Breaking capacity 2.5 KV), supply and fixing. | 56 | No. |
| Steel Box (16 BG) for main switch, distribution board and meter, Type A, as per drawing in Figure 25-14, duly painted with primer and two coats of synthetic enamel paint, supply and fixing. | 5 | No. |
| LT Switch Board with 1250 A, MCCB, incoming switch, complete with thermal over current release, adjustable magnetic short circuit release, shunt trip coil, CT ratio 1000/5, volt meter and Amp-meter with selector switches, earth fault relays, complete with TP, neutral common bus bar, including upto 06 outgoing with neutral link, 3-Phase MCCB switches, switch board steel sheet factory wired, painted and installed, complete including making connection, supply and fixing. | 4 | No. |
| MCCB 4 Pole, 500 / 600 V, 50/60 Cycles, complete with thermal and magnetic trip 250A (Breaking capacity 2.5 KV), supply and fixing. | 16 | No. |
| MCCB 4 Pole, 500 / 600 V, 50/60 Cycles, complete with thermal and magnetic trip 100A (Breaking capacity 2.5 KV), supply and fixing. | 3 | No. |
| MCCB 4 Pole, 500 / 600 V, 50/60 Cycles, complete with thermal and magnetic trip 400A (Breaking capacity 2.5 KV), supply and fixing. | 3 | No. |
| Wiring in conduit surface, concealed, flame proof, with single core PVC insulated cable, installed and connected complete (excluding conduit) single core cable, 2.5 mm² (For Earthing), supply and fixing | 450 | Mtr |
| Wiring in conduit surface, concealed, flame proof, with single core PVC insulated cable, installed and connected complete (excluding conduit) single core cable, 4 mm² (For Earthing), supply and fixing | 360 | Mtr |
| Wiring in conduit surface, concealed, flame proof, with single core PVC insulated cable, installed and connected complete (excluding conduit) single core cable, 25 mm² (For Earthing), supply and fixing | 600 | Mtr |
| Cable electric LT, PVC insulated, PVC sheathed, un-armoured, overall PVC 600/1000 V, with stranded copper conductor 35 mm², but 3½ core, laid in trenches complete with bricks, sand (excluding cost of excavation), supply and fixing. | 90 | Mtr |
| do but 70mm | 270 | Mtr |
| do but 95mm | 360 | Mtr |
| do but 120 mm | 540 | Mtr |
| Supply, installation, testing and commissioning of DC Cable 6mm² double XLPO insulated and tin coated for solar electric energy system, complete in all respect as specified. | 14589 | Mtr |
| Lightning Arrester set of three pieces, complete, with all accessories, | 8 | No. |
| Earthing :complete as described in Para 24.16 of the Specifications, with 3/0 SWG copper conductor, supply and fixing. | 13 | Job |
| Excavation in hard soil for Cables | 151 | Cum |
| Polyethylene Pipe (PE-100), 75 mm dia, Class PN-10 / SDR-17 (excluding cost of excavation), supply and fixing. | 360 | Mtr |
| Conduit, 50 mm dia, heavy gauge Class-"B", screwed, solid drawn, complete with all bends, tees, boxes saddels etc., stove enamelled for surface wiring, supply and fixing (fittings shall be flame proof and conform to BS No. 229 and 889). | 1170 | Mtr |
| Battery Controller:BEES battery controller as SigenStack BC M2-0.5C-BST supply fixing complete in all respect | 4 | No. |
| Gateway (For Genset Synchronization) 120KW supply and fixing, complete in all respect | 4 | No. |
| Communication Cable for CT supply and fixing | 1000 | No. |
| AC Surge Protection Devices Type II, supply and fixing, complete with all respect | 9 | No. |
| Net Metering: Provision for statutory charges payable to K-Electric and/or other Competent Authority in connection with grid interconnection and net-metering approval of the Solar PV System, including application fees, processing charges, bidirectional revenue metering charges, statutory inspection/testing charges (where levied by the utility), and any other mandatory statutory charges required for grant of grid interconnection approval. | 1 | Job |