Loading…
Military Lands & Cantonments (ML&C) Military Land & Cantonments Deptt. (ML&C) Rawalpindi - Pakistan
Military Land & Cantonments Deptt. (ML&C) · Rawalpindi
| Item | Qty | Unit |
|---|---|---|
| Connectors, consisting of mould resin, padding tape, funnels and ferrules etc as specified for PVC unarmoured LT cable, Single core, 25 mm² to 35 mm², supply and fixing | 20 | Each |
| Bi-directional Meter | 21 | Each |
| DC Earth, complete as described in Para 24.16 of the Specifications, with 3/0 SWG copper conductor, supply and fixing. | 22 | Each |
| AC Earth, complete as described in Para 24.16 of the Specifications, with 3/0 SWG copper conductor, supply and fixing | 23 | Each |
| MISC ITEMS | 24 | Job |
| Installation, Testing and Commissioning | 25 | Job |
| Net metering services | 26 | Job |
| Operation and Maintenance Services | 27 | Job |
| O&M Training | 28 | Job |
| 10% above MES Schedule 2025 (Rs) |
| 18 |
| Job |
| Hybrid Inverter | — | KW |
| PV Solar Module | — | KW |
| PV Mount Structure | — | KW |
| Lithium-Ion Battery | — | KWh |
| AC Breaker | — | No. |
| DC Wire with PV | — | Mtr |
| AC Wire | — | Mtr & mm Sq |
| Cable Tray | — | Mtr |
| Genset Controller / Synch Panel | — | No. |
| 0.4kV LV Panel | — | No. |
| DC Distribution Box | — | No. |
| 3 phase Hybrid 80 kW Sineng Inverter with Remotely Monitoring Devices | 1 | kW |
| Tier 1 Manufacturer according to bloomberg latest issued rankings with IEC 61215 Compliance and not less than 600 W N-Type Half Cut PV module | 2 | kW |
| Roof Top Galvanized Elevated Structure | 3 | kW |
| Lithium-ion Battery for critical load installed with Hybrid system | 4 | kW. |
| Genset Controller for Hybrid Inverter | 5 | Job |
| IP65 galvanized iron AC combiner Cabinet, 1 IN 1 Out The size of cabinet : H*L*D ft (4*2.5*2.5)/ DB as per layout Gauge : 16 AWG, Color : RAL 6021 Mounting type = ground mounted Details of breakers and SPD to be in housed in cabinet, Others specs:RYB Indicator, Digital Ammeter and Voltmeter =Yes, AC grounding bus bar =Yes(length =1 ft, to be placed at the left bottom of the DB),DC grounding Bus bar=Yes | 6 | Nos. |
| IP54 GI DB for each inverter for placing DC strings Wall mount, single door with lock and with complete fitting scheme/ railing for DC breakers | 7 | Nos. |
| AC Breakers 160A | 8 | Nos. |
| AC Breakers 250A | 9 | Nos. |
| DC Breakers with Fuses and all other safety equipment | 10 | Job |
| 06 mm Sq. DC flexible wire 1500V DC Copper conductor, Cu XLPO/XLPEO | 11 | Mtr. |
| AC Cable 4-C Cu, PVC/PVC 0.6/1 kV, 95 mm Sq. AC stranded | 12 | Mtr. |
| AC Cable 4-C Cu, PVC/PVC 0.6/1 kV, 16 mm Sq. AC stranded | 13 | Mtr. |
| Earthing of Solar System | 14 | Nos. |
| 16 AWG Galvanized iron with flat cover, perforated, size (W*D)inch 4*2 for laying string wires | 15 | Mtr |
| DB’s for Energy Source and Load for Back equipment, Racks for BESS, completed with all aspects | 16 | Nos. |
| Net Billing Services complete in all aspects along with bidirectional meters and NEPRA license | 17 | Job. |
| Complete project installation and commissioning till handover of the project to client | 18 | Job. |
| 11% above MES Schedule | 19 | Job. |
| 3 phase Hybrid Sineng Inverter with Remotely Monitoring Devices | 1 | kW |
| Supply & fixing of Geset Gateway / Synch Controller, completed with all aspects | 5 | Job |
| 06 mm Sq. DC flexible wire 1500V DC Copper conductor, Cu XLPO/XLPEO | 10 | Mtr. |
| AC Cable 4-C Cu, PVC/PVC 0.6/1 kV, 95 mm Sq. AC stranded | 11 | Mtr. |
| AC Cable 4-C Cu, PVC/PVC 0.6/1 kV, 16 mm Sq. AC stranded | 12 | Mtr |
| Earthing | — | Job |
| Complete earthing of Solar System including lighting arresters with 15mm dia copper, 150 cm long with copper base, 75mm x 40 mm x 30 mm, fixed complete with brass, bolts, supply and fixing | 13 | Nos. |
| 16 AWG Galvanized iron with flat cover, perforated, size (W*D)inch 4*2 for laying string wires | 14 | Mtr |
| DB’s for Energy Source and Load for Back equipment, Racks for BESS, completed with all aspects | 15 | Nos. |
| Net Billing Services complete in all aspects along with bidirectional meters and NEPRA license | 16 | Job. |
| S/F of UPVC pipe including band, sockets and clips as per site req. | 17 | Job |
| Change Over (300A) | 18 | Job |
| 11% above on MES Schedule | 19 | Job |
| Supply, installation, testing and commissioning of PV panel Tier-1 for solar electric energy system, complete in all respect as specified | 1 | Watt |
| Supply, installation, testing and commissioning of Lithium Iron Phosphate Battery for solar electric energy system, complete in all respect as specified | 2 | Watt |
| String Inverter 3 phase Hybrid Inverter Combination with Remote Monitoring Devices 100KW | 3 | Each |
| Communication Box | 4 | Each |
| Supply and Installation of GI/Aluminium frame structure (Roof Top Elevated Structure) including concrete work for solar electric energy system, complete in all respect as specified | 5 | Watt |
| Air termination for Lightning Conductor, with 15 mm dia copper rod, 150 cm long, with gunmetal copper base, 75 mm x 40 mm x 30 mm, fixed complete, with brass bolts, supply and fixing. | 6 | Each |
| 0.4KV LV Panel | 7 | Each |
| Distribution Board, steel sheet (16 BG) with hinged cover, having locking arrangement, enamel painted, suitable for housing of different capacities of MCCBs etc (as required), supply and fixing | 8 | Each |
| DC Breakers | 9 | Each |
| Supply, installation, testing and commissioning of DC Cable 6mm² double XLPO insulated and tin coated for solar electric energy system, complete in all respect as specified | 10 | Mtr |
| Cable electric LT PVC insulated, PVC sheathed, steel wire armoured, overall PVC 600/1000 V, with stranded copper conductor, 150 mm², 4 core, laid in trenches, complete with bricks, sand (excluding cost of excavation) supply and fixing | 11 | Mtr |
| Cable electric HT, 11 KV stranded Copper conductor XLPE insulated, extruded PVC bedded, steel wire armoured and PVC sheathed overall Single core, 70 mm² laid in trenches complete with bricks, sand (excluding cost of excavation) supply and fixing | 12 | Mtr |
| Cable electric HT, 11 KV stranded Copper conductor XLPE insulated, extruded PVC bedded, steel wire armoured and PVC sheathed overall Single core, 16 mm² laid in trenches complete with bricks, sand (excluding cost of excavation) supply and fixing | 13 | Mtr |
| Wiring in conduit surface, concealed, flame proof, with single core PVC insulated cable, installed and connected complete (excluding conduit) single core cable, 6 mm², supply and fixing | 14 | Mtr |
| Wiring in conduit surface, concealed, flame proof, with single core PVC insulated cable, installed and connected complete (excluding conduit) single core cable, 16 mm², supply and fixing | 15 | Mtr |
| Stringing, straining, tensioning and binding Copper conductor, bare solid or stranded 4 SWG, supply and fixing | 16 | Mtr |
| Cable tray out of 16 Guage, GI sheet, without cover, complete in jointing plates | 17 | Mtr |
| Conduit 50 mm dia, heavy gauge Class "B" screwed complete with all bends, tees, boxes, saddles etc, stove enamelled for Concealed wiring, supply and fixing | 18 | Mtr |
| Conduit 25 mm dia, heavy gauge Class "B" screwed complete with all bends, tees, boxes, saddles etc, stove enamelled for Concealed wiring, supply and fixing | 19 | Mtr |
| AC Breaker | 4 | Nos. |
| DC Wire with PV | 300 | Mtr. |
| Battery Instl System | — | No. |
| Complete Conduit | — | Job |
| Net billing Services | — | Job |
| Change Over Switch | — | No. |
| Hybrid Inverter | 80 | kW |
| PV Solar Module | 80 | kW |
| PV Mount Structure for ROOFTO P | 80 | kW |
| Lithium- Ion Battery | 80 | kW. |
| Geset Controller | 1 | Job |
| 0.4kV LV Panel | 4 | Nos. |
| DC Distributio n Box | 4 | Nos. |
| Hybrid Inverter | 160 | kW |
| PV Solar Module | 160 | kW |
| PV Mount Structure for ROOFTOP | 160 | kW |
| Lithium-Ion Battery | 60 | kW. |
| Geset Gateway / Synch Controller | 1 | Job |
| DC Distribution Box | 4 | Nos. |
| AC Breaker | 6 | Nos. |
| DC Wire with PV | 7000 | Mtr. |
| AC Wire | 400 | Mtr. |
| Hybrid Inverter | 100 | kW |
| PV Solar Module | 100 | kW |
| PV Mount Structure for ROOFTOP | 100 | kW |
| Lithium-Ion Battery | 40 | kW. |
| 0.4kV LV Panel | 2 | Nos. |
| DC Distribution Box | 2 | Nos. |